Entry Doors: Must
lock securely. Check the weather-stripping. If there are gaps
that let air in, weather-stripping must be applied. Check the
doorjamb and strike plate for defects. Be sure to change the
lock(s) between tenants.
Windows :
Those designed to open must open and have a permanent lock
attached (sticks and thumbscrews are not accepted as locking
devices). The windowpanes must not be broken or cracked. Screen
are required on all opening windows. The windows should not be
obstructed. TYPICALLY, BASEMENT ROOMS used
as BEDROOMS are illegal. WINDOWS ARE A MEANS OF ESCAPE IN A FIRE
and A MEANS FOR THE FIRE DEPARTMENT TO ENTER.
Electrical Hazards
: Units must be free of electrical hazards. All outlets and
switches must have cover plates, intact and secured to the wall.
There can be no exposed wiring. All light fixtures must work
and be properly mounted to the wall or ceiling. Breaker boxes
must have all open spaces filled with knockouts or blank spacers
and must have no exposed wires.
Oven/ Range :
The range and oven should be clean so they do not constitute a
fire hazard. Burners must lay flat and all elements must be
working properly. All knobs and dials should be on the
appliance. Filter screens should be installed in front of fans
and clean.
Refrigerator :
The rubber gasket around the door should be intact and fit
snugly. Loose and/or cracked gaskets must be replaced. The
kickplate at the bottom of the refrigerator must be secured
properly.
Heating and Plumbing
: The heating system must be in working order and provide
adequate heat. All heat sources should be clear of furniture,
bedding, clothing and other items. Oil, gas and propane furnaces
must be safe and professionally serviced at least once every two
years. Verification of service must be provided. Plumbing
fixtures (sinks, toilets, showers, etc.) should be free of leaks
and functioning / caulked and free from mold.
Hot Water Heaters
: Must have a pressure relief valve and discharge line that
extends to within 6 inches of the floor. Discharge tubing must
be of the appropriate type of material - either galvanized
steel, copper or CPVC piping (not PVC). There should be no
exposed wires. In addition, flammable material should not be
stored near the hot-water tank.
Flooring :
Carpets that are frayed or torn, or vinyl, tile or linoleum that
would be a tripping hazard must be replaced or repaired. Exposed
carpet tacks or thresholds that are loose must be repaired.
Please check and repair floors that have dry rot (commonly found
in the bathroom, around the bathtub and toilet).
Smoke Detectors
: A smoke detector, with a tester button, must be on each floor
of the unit. If a tenant has impaired hearing, a smoke alarm
designed for the hearing-impaired must be mounted in the bedroom
occupied by that individual. RentLaw.com
is going to add to that in many instances, you will be required
to have a CARBON Monoxide Detector and an APPROVED Fire Extinguisher.
A general rule: SAFETY FIRST. See
our guide to Fire Safety for more details.
Ventilation :
Inoperable bathroom fans or no ventilation (i.e. window) would
result in a fail rating.
Decks, Railings, Steps
: Stairways with four or more steps must have a handrail. The
handrail must run the length of the stairway and be securely
supported. Decks, rails and steps must be free of dry rot and
tripping hazards. Railings are required for decks, porches or
steps that are more than 30 inches from the ground.
Peeling Paint:
HUD requires that a home built prior to 1978 have no
deteriorated or peeling paint inside or out if children under
the age of six will occupy it.
Let's add in some other
pointers:
MOLD - See our guide
to Mold . Be
sure to clean up mold and identify the cause of the mold. Check
Ventilation and all plumbing and heating.
EXTERIOR:
Free from Garbage. Paint and general condition of house and
roof.
BE
SMART. MAKE THOSE REPAIRS AS YOU GO. FIX IT ONCE. SAVE WHERE YOU
CAN, BUT A FEW EXTRA CENTS SPENT TODAY MAY SAVE YOU A BIGGER
EXPENSE LATER.
|